Boiler feed and blowdown water parameters

 
Boiler feed  and blowdown water parameters 


All Types Of Boiler feed and blowdown water parameters 


 Boiler blowdown water parameters


[1] Lancashire boiler maximum TDS is                10000 ppm.
[2] Two-pass economic  Boiler                    maximum TDS is 4500 ppm
[3] Packages 3 pass economic Boiler      maximum TDS is 3500 ppm 
[4] The low-pressure water tube Boiler's maximum TDS is 3000 ppm
[5] Coil boiler and steam generators          Maximum Tds is - 2000 ppm 
[6] Medium pressure water tube Boiler     Tds - 1500 ppm.
[7] The high-pressure water tube Boiler            Maximum Tds is -1000 ppm.


high-pressure boiler water parameters
*Acidic water is corrosive and alkaline water is more prone to scaling. 
*Therefore Boiler feed water is kept slightly alkaline to avoid corrosion of boiler tubes.

All Types of small Boilers & Low-pressure boilers blow down water PH-10.5 to 11.5.
 * High-pressure Boiler blowdown          water PH-9.5 to 10.5

TH- Total Hardness in Blowdown water is (Nil) means Zero.

*Residual Sulphite As(Na2o3) 
   20-30mg/ltr 

  *Phosphates (Po4) (Added) 
     15-30 mg/Itr

*Residual Hydrazine as (N2H4)
   0.1--0.5 mg/It 

*Silica as(Si02) 
  15.0mg/Itr

*Oxygen (02) 0.007 %

 *Conductivity < 10 Micro siemens per Centimeters


BOILER FEEDWATER PARAMETERS 

*Low pressure &Shell type&Medium pressure water tube, Boilers maximum PH -8.5 -9.5 MAXIMUM (TDS ) -300 ppm 

* Nowadays Better Result to all Industries Maintain <100 ppm
TH-Total Hardness Maximum
      0-5ppm 
*Total Alkalinity null as(caco3) 20%-60 %maximum Dissolved
* Oxygen 0.02 mg/ltr milligram per liter 
Silica(as Sio2) 0.5 mg/ltr milligram per liter


HIGH-PRESSURE BOILER FEED WATER PARAMETERS

High-pressure boiler blowdown water parameters 